Home   |  News   |  Jobs and Careers   |  Project Study   |   Products & Services   |   CCL Group
Products & Services

Home » Product & Services » Post-Tensioning Systems > CCL Post-Tensioned Floor Slabs For Buildings>
CCL Slab Design

CCL provide the complete design for a post-tensioned solution. CCL’s design team has the experience and the expertise, gained by working on projects around the world, to provide you with a prompt and effective design solution.

We utilise state-of-the-art design programs that are continuously updated to reflect the latest international construction codes of practice.

CCL specialists are available to help structural engineers determine the best option from an early design stage, through extensive value engineering in order to meet specific requirements for each project. CCL can provide a detailed scheme with sufficient information for tender purposes. Upon execution, CCL’s specialised design team will develop the design and provide shop drawings for construction.

Post-tensioning tendons are virtually replaced in the slab by the set of forces they exert on it: compression along the slab perimeter, upward forces in the field and downward forces over the supports.

Several elastic methods of analysis can be used to determine stresses in slabs under gravity loads and equivalent post-tensioning actions such as the Equivalent Frame Method (EFM) and the Finite Element Method (FEM). Stresses and deflections resulting from the elastic analysis are checked under Service Limit State (SLS) against allowable values imposed by the adopted code of practice.

solid_flat_slab.jpgBANDED_COFFERED_FLAT_SLAB.jpgBANDED_FLAT_SLAB.jpgBEAM_AND_SLAB.jpgCOFFERED_SLAB_WITH_drop_panels.jpgRIBBED_SLAB.jpgSOLID_FLAT_SLAB_WITH_DROP_PANELS.jpg

Critical sections are checked under Ultimate Limit State (ULS) and where a lack of resistance occurs; it is compensated by localised additional ordinary reinforcement. The punching shear is checked and if the corresponding resistance is not sufficient, it is catered for by additional reinforcement, shear studs or increased concrete thickness (drop caps).

When an analysis is satisfactorily completed, structural detailing is carried out to show the slab’s layout and dimensions, tendons’ distribution and profiles, details of ordinary reinforcement, jacking forces and corresponding elongations in tendons due to stressing.

2_WAY_BANDED_1_WAY_DISTRIBUTED.jpg1_WAY_BANDED_1_WAY_DISTRIBUTED.jpg 2_WAY_DISTRIBUTED.jpg

             2 Way Banded                              1 Way Banded                           2 Way Distributed

                                                               1 Way Distributed

The CCL post-tensioned slab systems can be integrated into any type of slab such as; flat slab, ribbed slab, coffered slab or waffle slabs. The slab may include drop caps, drop panels or band beams to produce optimal configurations.

Partners | About Us | Contact Us | Links | Privacy Policy | Client Login


               CCL Products   CCL Projects   Site Content